type | Square type capacitive type unshielded type |
---|---|
Hysteretic | 0.6 to 5 mm |
Repeat distance accuracy | ± 0.2 mm or less |
Detectable object | liquid |
Type of power supply | DC 3 wire type |
Power-supply voltage | 12 to 24 VDC (ripple (pp) 10% or less) |
Operating voltage range | DC 10.8 to 30 V |
Current consumption | 12 mA or less |
Control output (output format) | NPN open collector |
Control output (switching capacity) | 100 mA |
Control output (residual voltage) | 1 V or less (load current 100 mA, code length 2 m) |
Indicator light | Detection indicator light (orange) |
action mode | No |
Ambient temperature range | When used: 0 to 55 ℃ Storage: -10 to 65 ℃ (However, do not freeze) |
Ambient humidity range | When used: 25 to 85% RH Storage: 25 to 85% RH (with no condensation) |
Influence of temperature | Change in detection level within the temperature range of 0 to + 55 ° C is ± 4 mm (± 6 mm for pure water of pipe diameter φ 8) (based on the detection distance at 23 ° C, with pure water and 20% salt water) |
Effect of voltage | ± 0.5 mm of detection level within the range of rated voltage ± 10% (based on detection distance at rated power supply voltage) |
Insulation resistance | Between charging unit and casing: 50 MΩ or more (DC 500 V mega) |
Withstand voltage | Between charging unit and casing: AC 500 V 50/60 Hz 1 min |
Vibration (durability) | 10 to 55 Hz Double amplitude 1.5 mm X, Y, Z direction 2 h |
Impact (durability) | 500 m / s ** 2 X, Y, Z three times in each direction |
Protective structure | IEC standard: IP66 |
Connection method | Code pullout type (Cord length: 2 m) |
Mass (packing state) | Approximately 70 g |
Material | Case: Heat resistant ABS |