type | Standard type |
---|---|
Output | 1 output |
Detection distance (reference value) | E32-T11R: 3000mm (GIGA mode) E32-T11R: 1500Mm (standard mode) E32-T11R: 1050Mm (high-speed mode) E32-T11R: 280Mm (fastest mode) E32-D11R: 1260Mm (GIGA mode) E32-D11R: 520Mm (Standard mode) E32 – D11R: 360 mm (high speed mode) E32 – D 11 R: 100 mm (fastest mode) |
light source | Red four element light emitting diode (emission wavelength: 625 nm) |
Power-supply voltage | DC 10 to 30 V (including ripple (pp) 10%) |
power consumption | Electric function ON: 650 mW or less ( when the power supply voltage is 24 V, consumption current is 27 mA or less) Eco function LO: 750 mW or less (at power supply voltage 24 V, consumption current 31 mA or less) Normal mode: 840 mW or less |
action mode | ON at the time of incoming light / ON switching type at light blocking type |
Control output | NPN open collector Load current 100 mA or less (1 to 3 units connected) / Load current 20 mA or less (4 or more units connected) Residual voltage 1 V or less (Load current less than 10 mA) / Residual voltage 2 V or less (Load current 10 to 100 mA) |
Protection circuit | Output short circuit protection, output reverse connection protection, power supply reverse connection protection |
Indicator light | Main digital display (white), sub digital display (green), OUT indicator (orange), L / D indicator (orange), ST indicator (blue), DPC indicator (green) |
Number of units capable of preventing mutual interference | 10 (Unusable in fastest mode) |
function | Zero Reset, Setting Reset, Power Tuning, Auto Power Control, Dynamic Power Control Function, Timer, Eco Mode, Bank Switching, Output 1 Setting, Hysteresis Setting |
Sensitivity adjustment | Smart tuning or manual adjustment |
Ambient illuminance to use | Light receiving surface illuminance incandescent lamp: 20000 lx or less, sunlight: 30000 lx or less |
Ambient temperature range (when used) | 1 to 2 units Connected -25 to 55 ° C 3 to 10 units Connection time -25 to 50 ° C 11 to 16 units Connection time -25 to 45 ° C 17 to 30 units Connection time -25 to 40 ° C |
Ambient temperature range (during storage) | -30 to 70 ° C |
Ambient humidity range | When used: 35 to 85% RH Storage time: 35 to 85% RH |
Insulation resistance | 20 MΩ or more (DC 500 V Mega) |
Connection method | Code pullout type (Cord length: 2 m) |
Withstand voltage | AC 1000 V 50/60 Hz 1 min |
Vibration (durability) | 10 to 55 Hz Double amplitude 1.5 mm X, Y, Z direction 2 h |
Impact (durability) | 500 m / s ** 2, 3 times in X, Y, Z directions |
Mass (packing state) | Approximately 115 g |
Mounting method | DIN rail or optional metal fittings (E39 – L143) |
Material | Case: Polycarbonate (PC) Cover: Polycarbonate (PC) Cable: PVC |
accessories | instruction manual |