WL01G2 Omron limit switch

WL01G2

WL01G2 Omron limit switch

SKU: 10 Category:
Shape/Structure General-purpose Limit switches
Service life General type
Actuator Roller lever
17.5 dia. x 7 Sintered stainless steel roller 38 R
Frequency 50/60 Hz
Contact form SPST-NO/SPST-NC
Load Micro load
Ratings (AC): Non-Inductive load Rated voltage: 125 VAC / Resistive load: 0.1 A(NC) 0.1 A(NO)
Ratings (DC): Non-Inductive load Rated voltage: 30 VDC / Resistive load: 0.1 A(NC) 0.1 A(NO)
Inrush current NC: 15 A
NO: 10 A
Protective circuit Classification of protection against electric shock: Class I
Short-circuit protective device: 10 A fuse type gG or gI (IEC269)
Conduit size G1/2
Earth terminal Without ground terminal
Ambient temperature Operating: -10 to 80 ℃
(no icing)
Ambient humidity Operating: 35 to 95% RH
(no condensation)
 
Permissible operating frequency (Mechanically) 120 operations / 1 minute
Permissible operating frequency (Electrically) 30 operations / 1 minute
Contact resistance (Initial value) 50 mΩ max.
Insulation resistance 100 MΩ min.
(at 500 VDC)
Dielectric strength Between each terminal of the same polarities: 600 VAC 50/60 Hz 1 min
Between each terminaland ground: 1,500 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 1,500 VAC 50/60 Hz for 1 min
Impulse withstand voltage Between each terminaland ground: 2.5 kV
Between each terminal and non-live-metallic part: 2.5 kV
Durability (Mechanically) 10,000,000 operations min.
(Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)
Durability (Electrically) 1,000,000 operations min.
(Temperature, Humidity conditions: 5 to 35 ℃, 40 to 70% RH)
Vibration resistance (Malfunction) 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (Destruction) 1000 m/s**2 min.
Shock resistance (Malfunction) 200 m/s**2 max.
Pollution degree 3 (EN60947-5-1)
Degree of protection IP67
 
Operating Force (OF) Standard value 9.81 N max.
Release Force (RF) Standard value 0.98 N min.
Pre-Travel (PT) Standard value 10 +2/-1 °
Over-Travel (OT) Standard value 65 ° min.
Movement Differential (MD) Standard value 7 ° max.