capacity | 180 W |
---|---|
efficiency | 85% TYP. (When 100 VAC is input) 88% TYP. (When 200 V AC is input) |
Rated input voltage | AC 100 to 240 V |
Input voltage allowable variation range | AC 85 to 264 V DC 80 to 370 V |
Caution on DC input | The applicable range of EC directives and various safety standards (UL, EN, etc.) is AC 100 to 240 V (AC 85 to 264 V). |
frequency | 50/60 Hz |
Input current | 2.9 A or less 2.2 A Typ. (AC 100 V input) 1.6 A or less 1.1 A Typ. (AC 200 V input) |
Power factor | 0.9 |
Leakage current | 0.5 mA or less (at 100 V AC input) 1.0 mA or less (at 200 V AC input) |
Inrush current | 17.5 A or less 14 A Typ. (AC 100 V input) 35 A or less 28 A Typ. (AC 200 V input) |
Output voltage | DC 24V |
Voltage variable range | -10 to + 15% (at V. ADJ) |
Ripple noise voltage | 50 mV or less (at rated input and output) |
Output characteristics (input fluctuation) | 0.5% or less (Input AC 85 – 264 V at 100% load) |
Output characteristics (load fluctuation) | 1.5% or less (rated input, 0 to 100% load) |
Output characteristics (Ambient temperature fluctuation) | 0.05% / ℃ or less |
Output current | 7.5 A |
Start-up time | 570 ms Typical (AC 100 V input) 470 ms Typ (AC 200 V input) |
Output hold time | 58 ms Typ. (AC 100 V input) 62 ms Typ. (AC 200 V input) |
Overcurrent protection | 105 to 160% of the rated output current reverse L droop type, automatic restoration |
Overvoltage protection | Operates at 130% or more of the rated output voltage. Stop type recovery methods: re-input return (OFF time: 3min higher) |
Overheat protection | None |
Undervoltage detection output | None |
Power fail detection output | None |
Parallel operation | Impossible (backup operation possible, external diode necessary) |
Serial operation | Yes (Up to two units can be connected, external diode required) |
Withstand voltage | (Input Batch) and (Output Batch alarm output batch) between: AC3kV 1min (detection current 20 mA) (Input Batch) and (PE) between: AC2kV 1min (detection current 20 mA) (Output Batch alarm output batch) and (PE Between: AC 1 kV 1 min (detection current 30 mA) (batch output) and (Alarm output all at once): AC 500 V 1 min (detection current 20 mA) |
Anti-vibration | 10 to 55 Hz single amplitude 0.375 mm 3 directions 2 h each |
Insulation resistance | (Output collective · alarm output collective) and (input collective · PE): 100 MΩ or more (at DC 500 V) |
Construction | Cover type |
Impact resistance | 150 m / s ** 2, 6 directions 3 times each |
Output indicator light | Yes (color: green) |
cooling method | Natural air cooling |
I / O connection | Terminal block |
Mounting | DIN rail mounting |
Terminal block type | Screw terminal |
accessories | Terminal block cover |
Mass (main body) | Approximately 850 g |