S8VS-24024 omron power supply

s8vs-24024

S8VS-24024 omron power supply

SKU: 10 Category:
capacity 240 W
efficiency 85% TYP. (When 100 VAC is input) 
88% TYP. (When 200 V AC is input)
Rated input voltage AC 100 to 240 V
Input voltage allowable variation range AC 
85 to 264 V DC 80 to 370 V
Caution on DC input The applicable range of EC directives and various safety standards (UL, EN, etc.) is AC 100 to 240 V (AC 85 to 264 V).
frequency 50/60 Hz
Input current 3.8 A or less 2.9 A Typ. (AC 100 V input) 
2.0 A or less 1.5 A Typ. (AC 200 V input)
Power factor 0.9
Leakage current 0.5 mA or less (at 100 V AC input) 
1.0 mA or less (at 200 V AC input)
Inrush current 17.5 A or less 14 A Typ. (AC 100 V input) 
35 A or less 28 A Typ. (AC 200 V input)
Output voltage DC 24V
Voltage variable range -10 to + 15% (at V. ADJ)
Ripple noise voltage 140 mV or less (at rated input and output)
Output characteristics (input fluctuation) 0.5% or less (Input AC 85 – 264 V at 100% load)
Output characteristics (load fluctuation) 1.5% or less (rated input, 0 to 100% load)
Output characteristics (Ambient temperature fluctuation) 0.05% / ℃ or less
Output current 10 A
Start-up time 540 ms Typ (AC 100 V input) 
230 ms Typ (AC 200 V input)
Output hold time 64 ms Typ. (AC 100 V input) 
64 ms Typ. (AC 200 V input)
Overcurrent protection 105 to 160% of the rated output current reverse L droop type, automatic restoration
Overvoltage protection Operates at 130% or more of the rated output voltage. Stop type 
recovery methods: re-input return (OFF time: 3min higher)
Overheat protection None
Undervoltage detection output None
Power fail detection output None
Parallel operation Impossible (backup operation possible, external diode necessary)
Serial operation Yes (Up to two units can be connected, external diode required)
Withstand voltage (Input Batch) and (Output Batch alarm output batch) between: AC3kV 1min (detection current 20 mA) 
(Input Batch) and (PE) between: AC2kV 1min (detection current 20 mA)
(Output Batch alarm output batch) and (PE Between: AC 1 
kV 1 min (detection current 30 mA) (batch output) and (Alarm output all at once): AC 500 V 1 min (detection current 20 mA)
Anti-vibration 10 to 55 Hz single amplitude 0.375 mm 3 directions 2 h each
Insulation resistance (Output collective · alarm output collective) and (input collective · PE): 100 MΩ or more (at DC 500 V)
Construction Cover type
Impact resistance 150 m / s ** 2, 6 directions 3 times each
Output indicator light Yes (color: green)
cooling method Natural air cooling
I / O connection Terminal block
Mounting DIN rail mounting
Terminal block type Screw terminal
accessories Terminal block cover
Mass (main body) Approximately 1150 g