Type | Amplifier unit |
---|---|
Differential distance | 10% max. of sensing distance |
Power source | DC Three-wires models |
Power supply voltage | 12 to 24 VDC (ripple(p-p) 10% max.) |
Operating voltage range | 10 to 30 VDC |
Current consumption | 45 mA max. |
Control output (Output type) | NPN open collector |
Control output (Switching capacity) | 100 mA |
Control output (Residual voltage) | 0.7 V (30 VDC max.) |
Indicator | Detection indicator (red), Stability indicator (green) |
Operation mode | NO/NC selectable |
Ambient temperature | Operating: -10 to 55 ℃ Storage: -10 to 55 ℃ (no icing) |
Ambient humidity | Operating: 35 to 85% Storage: 35 to 85% (no condensation) |
Temperature influence | ±10% max. of sensing distance in temperature range of -10 to +55 ℃ (As the basis for sensing distance of 23 ℃) |
Voltage influence | ±1% max. of sensing distance in rated voltage range ±20%. (As the basis for sensing distance at standard power voltage) |
Insulation resistance | Between charged parts and the case: 50 MΩ min. at 500 VDC |
Dielectric strength | Between charged parts and the case: 1,000 VAC 50/60 Hz for 1 min |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude each in X, Y, and Z directions for 2 h |
Shock resistance | 100 m/s**2 for 3 times each in X, Y, and Z directions |
Connection method | Pre-wired models (Cable length: 2 m) |
Weight (Packed state) | approx. 50 g |
Accessories | Caution labels, Mounting bracket, instruction manual |
Amplifier unit/sensor head of combination | E2C-CR8A, E2C-CR8B, E2C-X1A, E2C-C1A, E2C-X1R5A, E2C-X2A |