type | Square type capacitive type unshielded type |
---|---|
Detection distance | 10 mm ± 10% |
Set distance | 0 to 7.5 mm |
Hysteretic | 15% or less of the detection distance |
Detectable object | Conductors and dielectrics |
Standard detection object | Grounded metal plate 50 × 50 × 1 mm |
Type of power supply | DC 3 wire type |
Power-supply voltage | 12 to 24 VDC (ripple (pp) 10% or less) |
Operating voltage range | 10 to 30 VDC |
Current consumption | 10 mA or less (24 VDC) |
Control output (output format) | NPN open collector |
Control output (switching capacity) | 100 mA (at 30 VDC) |
Indicator light | Detection indicator light (red) |
action mode | No |
Protection circuit | Reverse connection protection, surge absorption |
Ambient temperature range | At use: -10 to 55 ° C Storage: -10 to 55 ° C (but not freezing) |
Ambient humidity range | When used: 35 to 95% RH Storage: 35 to 95% RH (with no condensation) |
Influence of temperature | Change in detection distance within the temperature range of -10 to + 55 ° C is within ± 15% (based on the detection distance at 23 ° C) |
Effect of voltage | Within the range of the rated voltage ± 10%, the change in the detection distance is within ± 2.5% (based on the detection distance at the rated power supply voltage) |
Insulation resistance | Between charging unit and casing: 50 MΩ or more (DC 500 V mega) |
Withstand voltage | Between charging unit and casing: AC 500 V 50/60 Hz 1 min |
Vibration (durability) | 10 to 55 Hz Double amplitude 1.5 mm X, Y, Z direction 2 h |
Impact (durability) | 500 m / s ** 2 X, Y, Z three times in each direction |
Protective structure | IEC standard: IP66 |
Connection method | Code pullout type (Cord length: 5 m) |
Material | Case: Heat resistant ABS detection surface: Heat resistant ABS |
accessories | instruction manual |