HL-5050 omron limit switch

  • hl-5050
  • hl-5050

HL-5050 omron limit switch

SKU: 10 Category:
Shape / structure Vertical vertical type
lifespan General form
Actuator Variable rod · lever type
Rated frequency 50/60 Hz
Contact configuration 1a1b
load General load
Switching ability (AC) / no inductive load Rated load: 1.5 A (NC) 0.7 A (NO) Rated voltage: AC 250 V / resistance load: 5 A (NC) 5 A (NO) / lamp 
load: 5 A (NC) 1A (NC) 0.5 A (NO)
Switching capacity (AC) / inductive load Rated voltage: AC 250V / Inductive load: 3A (NC) 3A (NO) / Motor 
load: 1.5 A (N / A) (NC) 0.8 A (NO)
Switching ability (DC) / no inductive load Rated load: 3A (NC) 3A (NO) 
Rated voltage: 24 VDC / resistance load: 5 A (NC) 5 A (NO) / lamp load: 3 A NC) 3A (NO) 
Rated voltage: DC 125 V / resistance load: 0.4 A (NC) 0.2 A (NO) 
Rated voltage: DC 250 V / resistance load: 0.4 A (NC) 0.2 A (NO)
Switching capacity (DC) / inductive load Rated voltage: 
24 VDC / Inductive load: 4 A (NC) 4 A (NO) / Motor load: 3 A (NC) 4 A (NO) / Inductive load: 4 A (NC) NC) 3A (NO)
Allowable inrush current Normally closed (NC): 24 A 
Always open (NO): 12 A
Ambient temperature range At use: -5 to 65 ° C 
(but do not freeze)
Ambient humidity range When used: 35 to 95% RH 
(with no condensation)
 
Allowable operating speed 5 mm / s to 0.5 m / s
Allowable operation frequency (mechanical) 120 times / min or less
Allowable operation frequency (electrical) 30 times / minute or less
Contact resistance (Initial value) 25 mΩ or less
Insulation resistance 100 MΩ or more 
(DC 500 V Mega)
Withstand voltage Between terminals with the same polarity: AC 1000 V 50/60 Hz 1 min Between 
charging metal part and earth: AC 1500 V 50/60 Hz 1 min Between 
each terminal and non-charging metal part: AC 1500 V 50/60 Hz 1 min
Durability (mechanical) 10 million times or more 
(temperature and humidity condition: 5 to 35 ° C., 40 to 70% RH)
Vibration proof (malfunction) 10 to 55 Hz Double amplitude 1.5 mm
Impact resistance (durability) Up to 1000 m / s ** 2
Impact resistance (malfunction) Maximum 300 m / s ** 2
Protective structure IP65
 
Power required for operation (OF) Standard value Maximum 7.35 N
The power of return (RF) Standard value minimum 0.98 N
Movement to action (PT) Standard value Maximum 20 °
Motion after movement (OT) Standard value Minimum 50 °
Hysteresis movement (MD) Standard value Maximum 12 °
Operating characteristic condition When the length of the rod is 31.5 mm