capacity | 300 W |
---|---|
efficiency | 81% or more |
Rated input voltage | AC 100 to 240 V |
Input voltage allowable variation range | AC 85 – 265 V |
frequency | 50/60 Hz |
Input current | 4.3 A or less (AC 100 V input) 2.2 A or less (when 200 V AC is input) |
Power factor | 0.98 (AC 100 V input) 0.94 (AC 200 V input) |
Leakage current | 0.4 mA or less (at 100 VAC input) 0.75 mA or less (at 200 V AC input) |
Inrush current | 20 A or less (at 100 VAC input (at 25 ° C. cold start)) 40 A or less (at 200 VAC input (at 25 ° C. cold start)) |
Output voltage | DC 24V |
Voltage variable range | -20 to + 20% (at V.ADJ) |
Ripple noise voltage | 1.25% (pp) or less |
Output characteristics (input fluctuation) | 0.4% or less (Input AC 85 to 265 V at 100% load) |
Output characteristics (load fluctuation) | 0.6% or less (rated input, 0 to 100% load) |
Output characteristics (Ambient temperature fluctuation) | 0.02% / ℃ or less (at rated input and output) |
Output current | 14 A / 16.5 A (at peak current AC 200 V) |
Start-up time | 1000 ms or less (at rated input and output) |
Output hold time | 15 ms or more 20 ms Typ. (At rated input and output) |
Overcurrent protection | 120 to 160% of the rated output current reverse L droop type, automatic restoration |
Overvoltage protection | Operates at 140% or more of the rated output voltage. Stop type recovery methods: re-input return (OFF time: 3min higher) |
Overheat protection | Yes Return method: Restart input (OFF time: 3 minutes or more) or turn off / on remote control signal |
Undervoltage detection output | None |
Power fail detection output | Yes (open collector output DC 30 V or less 50 mA or less) |
Parallel operation | Yes (Up to 2 units can be connected) |
Serial operation | Yes (Up to two units can be connected, external diode required) |
Remote sensing | There |
Remote control | There |
Withstand voltage | Between AC 3 kV 1 min (detection current 20 mA) (batch input) and (PE): AC 2 kV 1 min (detection current 20 mA) (Batch output) and (PE): AC 500 V 1 min Between output (batch) and (RC): AC 100 V 1 min (Detection current 100 mA) (Batch output) and (PF): AC 500 V 1 min (Detection current 20 mA) |
Anti-vibration | 10 to 55 Hz single amplitude 0.375 mm 3 directions 2 h each |
Insulation resistance | (Output collective) and (input collective, PE): 100 MΩ or more (at DC 500 V) |
Construction | Cover type |
Impact resistance | 150 m / s ** 2, 6 directions 3 times each |
Output indicator light | Yes (color: green) |
cooling method | Forced air cooling |
I / O connection | Terminal block |
Mounting | Mounting on the bottom |
Terminal block type | Screw terminal |