S8VS-06024 omron power supply

  • s8vs-06024a
  • s8vs-06024a

S8VS-06024 omron power supply

SKU: 10 Category:
Power rating 60 W
Efficiency 84% TYP. (at 100 VAC input)
83% TYP. (at 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable input voltage variable range 85 to 264 VAC
80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz (47 to 450 Hz)
Rated input curren 1.3 A TYP. (at 100 VAC input)
0.68 A TYP. (at 200 VAC input)
Leakage current 0.5 mA max. (at 100 VAC input)
1.0 mA max. (at 200 VAC input)
Inrush current 14 A TYP. (at 100 VAC input)
28 A TYP. (at 200 VAC input)
Output voltage 24 VDC
Output voltage variable range -10 to +15% (With V. ADJ)
Ripple 70 mV max. (Under the rated I/O conditions.)
Static input variation influence 0.5% max. at 85 to 264 VAC input, 100% load
Static load variation influence 1.5% max. at rated input, 0 to 100% load
Ambient temperature variation influence 0.05 %/℃ max.
Rated output current 2.5 A
Start up time 620 ms TYP. (at 100 VAC input)
400 ms TYP. (at 200 VAC input)
Hold time 34 ms TYP. (at 100 VAC input)
158 ms TYP. (at 200 VAC input)
Overload protection 105% to 160% of the rated output current, Inverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection Operated at 130% min. of the rated output voltage, Shut-off
Resetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Undervoltage alarm output No
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
Series operation Yes (Up to 2 Power Supplies with external diode)
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)
Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)
Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 30 mA)
Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MΩ min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Structure Terminal blocks
Terminal type Screw terminal
Attachment Terminal block cover
Weight (Main) Approx. 330 g